Prelko
Dispatch Recommendations

Recommend, then approve. Never automatic.

When a peak is forecast, Prelko works out which levers you have - storage, flexible load, scheduled imports - and proposes a plan with megawatts and timings. Your operator approves, modifies or declines it, and executes it in your own systems.

Awaiting approvalREC-0419 · issued 11:05 · expires 16:30
Pre-dispatch for forecast peak 18:00-20:00 on the Eastern feeder group
ActionWindowMW
Charge battery storage, Substation 414:30-17:00+40
Discharge battery storage, Substation 418:00-20:00-90
Shift contracted flexible C&I load18:00-20:00-55
Peak before1,097 MW
Peak after951 MW
Capacity margin+129 MW
Approve Modify Decline Routed to shift operator
Expected effect

What the plan does to the curve.

Every recommendation shows the forecast with and without the proposed actions, so the operator can see exactly where megawatts move.

REC-0419 · forecast vs adjusted planPeak -146 MW
PRE-CHARGE / SHIFTPEAK WINDOWCAPACITY 1,080 MW12:0014:0016:0018:0020:0022:0000:00
Forecast without action Adjusted plan Capacity limit
Operator approval workflow

A person signs off on every megawatt.

Prelko has no write access to grid equipment. Approved plans are carried out through your SCADA, EMS or plant controls by the people who already run them.

Hard boundary

Recommendations expire if not acted on. Nothing is queued to run on its own, and declining a recommendation has no side effects.

01

Recommendation issued

Linked to the peak alert, with actions, windows, MW and expected effect.

02

Routed to the right operator

By asset, area or shift, with an expiry time based on the lead time.

03

Approve, modify or decline

Operators can change MW or timing; Prelko recalculates the effect instantly.

04

Executed in your systems

The operator carries out the plan through existing control systems.

05

Logged and scored

Decision, reason and outcome are recorded and appear in performance reports.

Levers Prelko can plan around

Uses the flexibility you already have.

Battery storage

Charge windows before the peak, discharge during it, within state-of-charge and cycling limits you set.

Flexible and contracted load

Demand-response contracts, interruptible industrial load and process schedules that can shift by hours.

Imports and network switching

Scheduled imports, inter-feeder transfers and generation re-dispatch, flagged for the relevant desk.

Dispatch questions

Can Prelko execute dispatch automatically?

No. Prelko forecasts and recommends. It does not directly control grid infrastructure or execute dispatch actions. Every recommendation routes to your operators for approval and execution.

How are the recommended actions chosen?

Prelko evaluates the levers you register, with their limits and costs, against the forecast peak and its uncertainty, and proposes the lowest-impact combination that keeps load within limits.

What happens if an operator modifies a plan?

The effect on the forecast is recalculated immediately. The modified plan and the reason given are stored alongside the original recommendation.

Walk through a recommendation on your network.

We model your storage and flexible load, then show the plan Prelko would have proposed for a recent peak.